Torque Converter
TS-2700 with Display |

|
The TS-2700 is the latest type of torque converter Despite compact designed body, it can provide a variety of functions on torque signal processing and signal outputs. Measurement results of torque and revolution can be directly read out on the display, furthermore, offers high accuracy (±0.2 % FS of rated range of torque detector) and repeatability. For outputs, 3 ways of outputs are available to use, analog voltage, BCD or RS-232C interface, its selection can expand capability of connection with external equipment such as a pen recorder, a sequencer, or a CPU. |
Features
-
Compact and lightweight
-
Both torque and revolution measurement and direct read-out on the display
-
3 ways of signal output, analog voltage, BCD or RS-232C interface
-
High accurate measurement for torque at ±0.2 % FS, for revolution at ±0.02 % FS
-
N-0 compensation function provided (zero value compensation for torque data over the revolution range)
-
Remote function enables following functions externally, selection of revolution direction, change of selection updating time of BCD output, synchronized operation of two of TS-2700, provision of interlock using output of READY and so on.
-
Setup conditions in both of CW/CCW can be stored on internal nonvolatile memory.
Specifications
| Torque Signal Measurement Section |
Input Section |
Type |
Phase-differential type torque detectors |
| Setup Section |
Zero value memory |
each for CW and CCW, with auto zero function |
| N-0 compensation |
5 points each for CW and CCW |
| Selection of zero value |
CW, CCW, EXT |
| Indication of decimal point |
automatic |
| Display Section |
Indicator |
Green LED, 7-segment |
| Display range |
0 to ±9999 |
| Display unit |
Nm |
| Display updating interval |
1s/10s/EXT, selectable |
| Accuracy (averaged for a second) |
±0.2 % FS ±1 count (when 0-compensation provided)
±0.5 % FS ±1 count (when 0-compensation not provided) |
| Revolution Signal Measurement Section |
Input Section |
REV
IN |
Type |
Signal from electromagnetic detector model MP-981 |
| Frequency |
1 Hz to 100 kHz
(accuracy is guaranteed from 10 Hz or higher) |
| INT |
SIG2 of torque detector |
| Setup Section |
No. of input pulse |
1 to 9999 P/R |
| Display Section |
Indicator |
Green LED, 7-segment |
| Display range |
0 to 99999 |
| Display unit |
r/min |
| Display updating interval |
1s/10s/EXT, selectable |
| Accuracy (averaged for a second) |
±0.02 % FS ±1 count |
| Output Section |
Analog Voltage Output Section |
Torque output level |
0 to ±10V/FS |
| Revolution output level |
0 to +10V/FS |
| Time constant |
Torque : 500ms/63ms
Rev. : 63ms |
| Linearity |
Torque : ±0.2 % FS (when N-0 compensation provided)
Rev. : ±0.1 % FS |
| Isolation |
Withstanding pressure of 250VDC for one minute
Common is used for torque and revolution |
| Proper Resistance |
10kΩ or more |
| Connector |
CO2 (BNC) plug |
| Digital Output Section |
Configuration |
BCD |
| Updating output |
every 1 second |
| Connector |
DX40-50P |
| RS-232C |
Baud rate |
9600bps |
| Data |
0-point/N-0 compensation/input of setup conditions, measurement values/output of setup conditions |
| Connecting cable |
AX-5022 RS-232C interface cable |
| Remote Function |
Input |
selection of revolution direction of CW/CCW, input of clear, input of trigger |
| Output |
output of trigger, output of ready |
| General |
Power supply |
100 to 240VAC, 50/60 Hz |
| Power consumption |
approx. 25VA (at 100VAC) |
| Insulation resistance |
10MΩ or more (at DC500V) |
| Withstanding voltage |
AC1500V for one minute |
| Operating temperature |
0 to +40°C |
| Storage temperature |
-10 to +55°C |
| Outer dimensions |
76 (W) x 142 (H) x 321 (D) mm |
| Weight |
Approx. 1.8 kg |
|